READ CAREFULLY AND RETAIN FOR FUTURE REFERENCES
INSTALLER’S MANUAL
Sensor Control BT
WV-SCBT
Wave Home Solutions
2421 Long Beach Road
Oceanside, NY
11572
Tel: 1-800-293-9577
Site: www.wavehomesolutions.com
Nov2/2009
MP 100933
Rev. 2
Vista de página 0
1 2 3 4 5 6 ... 14 15

Resumo do Conteúdo

Página 1 - WV-SCBT

READ CAREFULLY AND RETAIN FOR FUTURE REFERENCES INSTALLER’S MANUAL Sensor Control BT WV-SCBT Wave Home Solutions 2421 Long B

Página 2

SET HUMIDITY CONTROL AND EXHAUST CONTROL: Refer to the “Operating Instructions” Manual included with the unit to change speed and dehumidistat setti

Página 3 - INSTALLATION GUIDELINES

PLUG IN THE UNIT: Plug the unit into any 115V outlet. Note: A grounded extension cord with a maximum length of 10 feet may be

Página 4

SECTION B Installation situations to be aware of: PROTRUDING WALL OR BASEBOARD: In this situation, block or insert spacer on the back of the unit

Página 5

NOTE ABOUT CRAWL SPACE & BASEMENT COMBINATION: Depending on the square footage, the Sensor Control BT will be able to reduce the problems in the

Página 6

FOR TECHNICAL ASSISTANCE Do not attempt to service the Sensor Control BT yourself. If you are not sure about certain functions, call our qualified

Página 7

DO NOT INSTALL WV-SCBT NEXT TO REPLENISHMENT AIR SUPPLY. DO NOT DUCT INTO EXISTING EXHAUST DUCTS OR CHIMNEY. DO NOT PLACE WITHIN

Página 8

DESCRIPTON OF UNITS MODEL NO. BASEMENT WV-SCBT 1800 sq. ft. SPECIFICATIONS Sensor Control B

Página 9

INSTALLATION GUIDELINES SUMMARY OF KEY INSTALLATION FACTS – EXTREMELY IMPORTANT ! Unobstructed airflow and adequate replenishment air are essen

Página 10

REPLENISHMENT AIR TO BASEMENT FROM UPSTAIRS OF HOME • The damp air exhausted by the Sensor Control BT must be replaced by the warmer/drier air from

Página 11

• Make sure that no pipes, studs or wires are in the way. • Duct has to be dedicated and not combined with any other existing ductwork in operation

Página 12 - SECTION B

FACTORS TO CONSIDER WHEN SELECTING UNIT LOCATION: The installation must be done in the basement or the lowest, wettest, coldest level of your dwellin

Página 13

B.) Outside the building, find your pilot hole. Using a hole saw and the pilot hole as a guide,

Página 14 - NOT TO DO

NOTE: If the unit has to be shorter than 86.5” cut the top of the bottom part. ATTACH FLEX, PIPE AND VENT TOGETHER:

Página 15

FASTEN UNIT TO THE WALL: Leaving a 1 inch gap between the top of the unit and the ceiling (In case of a finished ceiling, leave a 1/